What was found
RT NR 2 SLAT O/B END RIB ATTACH ANGLE FOUND CRACKED AS MARKED. RHW NR 2 SLAT REMOVED. INNER SKIN OPENED FOR ACCESS. CRACKED ANGLE REMOVED NEW ATTACHMENT ANGLE FAB USING MAT'L 7075-0-0.050" PER DWG ARB1647. ANGLE HEAT TREATED. HOLES PICK-UP ON NEW ANGLE. NEW ANGLE REPROTECTED. NEW ANGLE PAINTED. NEW ANGLE INSTALLED ON RT NR 2 SLAT O/B END PER SRM 51-35-01 INNER SKIN REINSTALLED AND RHW NR 2SLAT INSTALLED AMM 27-80-20 REV 50.