What was found
INSPECTION TYPE-C FX AFT CARGO DOOR CUT-OUT AFT JAMB ALONG ABOVE LWR AFT SCUFF PLATE TO S-43L FOUND EDGE DAMAGED AS MARKED. EDGE DAMAGE AT S-43L ABOVE LWR AFT SCUFF PLATE OF FX AFT CGO DR CUT- OUT AFT JAMB TRIMMED OUT/SMOOTHENED IAW SRM53-50-00 FIG6 VOLI REV38. REWORKED AREA REPROTECT IAW SRM51-21-01 VOLII REV38. CARRY OUT HFEC INSP. REPAIR DOUBLERS FAB IAW SRM53-50-00 FIG6 VOLI REV38. REPAIR DOUBLERS INSTALLED IAW SRM53-50-00 FIG16 VOLI REV38 AND SRM51-31-01.