As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BLADDER CELL COMPT AT STA 1278.00 S-38R FOUND WEB SUPPORT FITTING CRACKED. REMOVED ATTACHED SUPPORT AND FASTENER ON FITTING PER SRM 51-31-01 V.II R .35.ANGLE P/N:AYB7035-12 M/F EXTRUDED 'T' P/N:S1362783 IAW DOUGLAS DWG AYB7035.FPI C/O PER DPS4.707 R.AW ON FAB ANGLE FOUND NO CRACK EVIDENT. ITEM INSPECTED,OK TO INSTALL. NEW ANGLE INSTALLED PER DWG AYB7035 AND SRM 51-3 1-01 V.II R.38. REINSTALLED REWORK AREA PARTS PER SRM 51-31-01 V.II R.38.