What was found
INSPECTION TYPE:C EMP-AFT ACC COMPT AFT BULKHEAD TOP OF LATCH HOUSING ASSY FOUND INTERCOSTAL CLIP CRACKED. CRACKED INTERCOSTAL CLIP REMOVED PER SRM 51-33-01 V.II R.38. NEW INTERCOSTAL CLIP P/N:AJC7345-2 MACHINED USING 7075T6511 STOCK IAW DOUGLAS DWG AJC7345. NEW INTERCOSTAL HOLE PICKUP PER SRM 51-31-01 V.II R.38. NEW INTERCOSTAL CLIP REPROTECTED PER SRM 51-21-01 V.II R.38. NEW INTERCOSTAL CLIP INSTALLED PER SRM 51-31-01 V.II R.38.