What was found
INSPECTION TYPE:N/A IFSD - NR 2 ENGINE T/R UNLOCK LIGHT ILLUMINATED DURING APPROACH TO DENVER. *S/D* ACCOMPLISHED T/R CHECK PER AMM 78-31-40-05 & RVDT AND STOW/DEPLOY SW ASSY. ADJ/TEST FUNCTION AND INDICATIONS NORMAL. CYCLED T/R SEVERAL TIMES PNEUMATICALLY WITH NO ABNORMAL INDICATIONS. THIS CLEARS DEFERRAL. A/C OK FOR SERVICE.