INSPECTION TYPE:N/A MAIN CARGO DECK FLOOR PANEL BETWEEN 10R AT 11R PUNCTURED 1 INCH. ACCOMPLISHED PERMANENT REPAIR PER SRM 53-10-20. OPS CHECK OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:N/A MAIN CARGO DECK FLOOR PANEL BETWEEN 10R AT 11R PUNCTURED 1 INCH. ACCOMPLISHED PERMANENT REPAIR PER SRM 53-10-20. OPS CHECK OK.