What was found
INSPECTION TYPE:C M/D BS 1954-1958 STR 1R STRINGER END FOUND CRACK. M/D BS 1920-1958 STR 1R STRINGER REPAIRED AS PER SRM 53-10-03 FIG 4. REPEAT INSPECTION IS REQUIRED AS PER SRM 53-10-03 FIG 4 TABLE 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D BS 1954-1958 STR 1R STRINGER END FOUND CRACK. M/D BS 1920-1958 STR 1R STRINGER REPAIRED AS PER SRM 53-10-03 FIG 4. REPEAT INSPECTION IS REQUIRED AS PER SRM 53-10-03 FIG 4 TABLE 3.