What was found
INSPECTION TYPE:C FX - MEC LT TUNNEL STA 300 S28AL STRINGER SPLICE FOUND SCRATCH MARK. FX - MEC LT TUNNEL BS 300 STR 28AL STRINGER SPLICE REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C FX - MEC LT TUNNEL STA 300 S28AL STRINGER SPLICE FOUND SCRATCH MARK. FX - MEC LT TUNNEL BS 300 STR 28AL STRINGER SPLICE REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.