What was found
INSPECTION TYPE:C FX - KEEL BEAM FAIRING SUPPORT LOWER SURFACE FOUND CORROSION AT STA 1405 TO STA 1416 LBL 16. CORROSION BLEND OUT 0.017 X .5 X 10 INCHES EXCEED SRM LIMIT. SUPPORT REPLACED AS PER SRM 51-10-01 PG 9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C FX - KEEL BEAM FAIRING SUPPORT LOWER SURFACE FOUND CORROSION AT STA 1405 TO STA 1416 LBL 16. CORROSION BLEND OUT 0.017 X .5 X 10 INCHES EXCEED SRM LIMIT. SUPPORT REPLACED AS PER SRM 51-10-01 PG 9.