What was found
INSPECTION TYPE:C FWD CARGO COMPT STRINGER FOUND CORROSION AT STA 920-930 S28L. CORROSION BLEND OUT 0.035 X .5 X 10 INCHES EXCEED SRM LIMIT. STRINGER 28L REPAIRED AS PER SRM 53-10-01 FIG 1, JUST BETWEEN BS 890-950.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C FWD CARGO COMPT STRINGER FOUND CORROSION AT STA 920-930 S28L. CORROSION BLEND OUT 0.035 X .5 X 10 INCHES EXCEED SRM LIMIT. STRINGER 28L REPAIRED AS PER SRM 53-10-01 FIG 1, JUST BETWEEN BS 890-950.