What was found
INSPECTION TYPE:C M/D BS 2140 STR 25-26L FRAME FOUND CRACK. CRACK LENGTH .5 INCH. M/D BS 2140 BEWTEEN STR 25-26L FRAME REPAIRED AS PER RS R53-62-35726. CONTINUE INSPECTION IS REQUIRED AS PER RS R53-62-35726 AND UPS EO B747-5310-26041.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D BS 2140 STR 25-26L FRAME FOUND CRACK. CRACK LENGTH .5 INCH. M/D BS 2140 BEWTEEN STR 25-26L FRAME REPAIRED AS PER RS R53-62-35726. CONTINUE INSPECTION IS REQUIRED AS PER RS R53-62-35726 AND UPS EO B747-5310-26041.