INSPECTION TYPE:C WAN#1068883 - REPLACE MAIN DECK CENTER SHEAR FLOOR PANEL P/N: 65B16351-12 LOCATED BTN BS1170 AND BS1253 LBL11 TO RBL11. CENTER SHEAR FLOOR PANEL REPAIRED AS PER BOEING MES 1-276210464-1 AND -2 AND RS R53-41-35733. REPEAT INSPECTION ON ALL PILOT HOLES IS REQUIRED UNTIL THE FLOOR SHEAR PANELS ARE REPLACED AND REFER UPS ENGINEERING FILE NO.747-53-20388.