What was found
INSPECTION TYPE:C BULK CARGO COMPT SLOPE PANEL SUPPORT SEVERAL LOCATION FOUND SURFACE CORROSION AT STA 1940 TO STA 2045 LBL 60 ANCHOR NUT AREA. CORROSION BLEND OUT 0.025" X .5" X 2" EXCEED SRM 53-10-01 FIG 1 LIMITS. SLOPE PNL SUPPORT BS 1940-2010 COR REMOVED & REPROTECTED AS PER SRM 51-10-01 & 51-10-02 ORG 0.050" BLEND OUT 0.005" X .5" X 1" WITHIN SRM 53-10-01 FIG 1 LIMITS. BS 2010-2070 COR SUPPORT REPLACED & INSTALLED AS PER SRM 51-10-01 PG 9 & 51-30-02.