What was found
INSPECTION TYPE:C M/D BS 960 RBL 9 TO 11 FLOORBEAM WEB FOUND CRACKED. CRACK LENGTH .75 INCH. M/D FLOORBEAM WEB REPAIRED AS PER SRM 53-10-07 FIG 11, JUST AT BS 960 BETWEEN RBL 6 AND RBL16 AREA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D BS 960 RBL 9 TO 11 FLOORBEAM WEB FOUND CRACKED. CRACK LENGTH .75 INCH. M/D FLOORBEAM WEB REPAIRED AS PER SRM 53-10-07 FIG 11, JUST AT BS 960 BETWEEN RBL 6 AND RBL16 AREA.