What was found
INSPECTION TYPE:C FWD CARGO COMPT AFT FIXED END STOP SUPPORT FITTING FOUND CRACK AT STA 980 RBL 45. CRACK LENGTH .75 INCH. FWD CARGO COMPT AFT FIXED END STOP SUPPORT FITTING REPLACED AS PER SRM 51-10-01 PG 9 AND INSTALLED AS PER SRM 51-30-02, JUST AT STA 980 RBL 45.