What was found
INSPECTION TYPE:C U/D RIGHT DOOR SILL BS 400 RBL TO FLOOR SUPPORT CHORD FOUND CRACKED. CRACK LENGTH: .75 INCH. FLOOR SUPPORT CHORD REPAIRED AS PER SRM 51-40-04 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C U/D RIGHT DOOR SILL BS 400 RBL TO FLOOR SUPPORT CHORD FOUND CRACKED. CRACK LENGTH: .75 INCH. FLOOR SUPPORT CHORD REPAIRED AS PER SRM 51-40-04 FIG 1.