What was found
INSPECTION TYPE:C M/D BS 1940 RBL 89 TO 92 FLOORBEAM UPPER SURFACE FOUND CORRODED. CORROSION BLEND OUT 0.082" X 1" X 1" EXCEED SRM LIMIT. M/D BS 1940 RBL 70" TO 92" RIGHT O/B FLOORBEAM REPAIRED AS PER SRM 51-40-04 FIG 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D BS 1940 RBL 89 TO 92 FLOORBEAM UPPER SURFACE FOUND CORRODED. CORROSION BLEND OUT 0.082" X 1" X 1" EXCEED SRM LIMIT. M/D BS 1940 RBL 70" TO 92" RIGHT O/B FLOORBEAM REPAIRED AS PER SRM 51-40-04 FIG 3.