As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C M/D BS 860 LBL 80-97 FLOORBEAM FOUND CORRODED. CORROSION BLEND OUT 0.040 X 2 X 2 INCHES EXCEED SRM 53-10-01 FIG 1 LIMITS. M/D BS 860 LBL 65 TO MOST LEFT O/B FLOORBEAM REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.