As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C RIGHT BS 340 U/D FLOORBEAM UPPER CHORD TO FRAME CONNECTION AREA FOUND 1EA FASTENER HOLE CRACKED AT U/D FLOORBEAM WEB APPROX .125 INCH. RIGHT BS 340 U/D FLOORBEAM WEB REPAIRED AS PER SRM 53-10-07 FIG 11, JUST BETWEEN RBL 52 AND RIGHT MOST O/B END.