What was found
INSPECTION TYPE:C M/D STA 1500 RBL 58 FLOOR SUPPORT INTERCOSTAL WEB ATT STIFFENER FOUND CRACKED. CRACK LENGTH .25 INCH. SUPPORT STIFFENER REPLACED AS PER SRM 51-10-01 PG 9 AND INSTALLED AS PER SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D STA 1500 RBL 58 FLOOR SUPPORT INTERCOSTAL WEB ATT STIFFENER FOUND CRACKED. CRACK LENGTH .25 INCH. SUPPORT STIFFENER REPLACED AS PER SRM 51-10-01 PG 9 AND INSTALLED AS PER SRM 51-30-02.