As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C RIGHT BS 900 FRAME TENSION TIE ATTACHMENT AREA AT FASTENER HOLE NR 1 THREE CRACKS FOUND AT FRAME LAYER. CRACK LENGTH .0625 AND 0.030 INCH. M/D BS 900 RIGHT FRAME BETWEEN STR 6R TO STR 11-5R REPAIRED AS PER RS R53-10-35750. CONTINUE INSPECTION IS REQUIRED AS PER RS R53-10-35750 AND UPS EO B747-5310-26134.