What was found
INSPECTION TYPE:C M/D STA2280 LBL39 FLOORBEAMS WEB REAR SIDE FOUND SEVERAL CRACKS, CRACK LENGTH 1/4". M/D BS 2280 LBL 39 FLOORBEAM WEB REPAIRED AS PER SRM 51-40-02 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D STA2280 LBL39 FLOORBEAMS WEB REAR SIDE FOUND SEVERAL CRACKS, CRACK LENGTH 1/4". M/D BS 2280 LBL 39 FLOORBEAM WEB REPAIRED AS PER SRM 51-40-02 FIG 1.