What was found
INSPECTION TYPE:C M/D BS 2300 LBL50 FLOORBEAMS WEB REAR SIDE STIFFENER FOUND CRACKED AS MARKED, CRACK LENGTH 3/8". M/D BS 2300 LBL50 FLOORBEAM WEB REAR SIDE STIFFENER REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D BS 2300 LBL50 FLOORBEAMS WEB REAR SIDE STIFFENER FOUND CRACKED AS MARKED, CRACK LENGTH 3/8". M/D BS 2300 LBL50 FLOORBEAM WEB REAR SIDE STIFFENER REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.