What was found
INSPECTION TYPE:C M/D STA2300-2320 LBL34 FLOOR SUPPORT FOUND SEVERAL CORROSION. CORROSION BLEND OUT 0.023" BY 1" BY 4" EXCEED SRM LIMIT. M/D BS 2300-2320 LBL34 FLOOR SUPPORT REPLACED AND INSTALED AS PER SRM 51-10-01 PG 9 AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D STA2300-2320 LBL34 FLOOR SUPPORT FOUND SEVERAL CORROSION. CORROSION BLEND OUT 0.023" BY 1" BY 4" EXCEED SRM LIMIT. M/D BS 2300-2320 LBL34 FLOOR SUPPORT REPLACED AND INSTALED AS PER SRM 51-10-01 PG 9 AND 51-30-02.