As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C LT BS 940 TENSION TIE NR 1 FASTENER HOLE FOUND CRACK AT FRAME RUNNING 7 O/C POSITION APPROX 0.040" IN LENGTH (LOOKING AFT). M/D BS 940 LT SIDE FRAME THROUGH FRAME DOUBLER, TENSION TIE, STEEL PLATE AND FAIL/SAFE CHORD HOLE OVERSIZED AND FASTENER INSTALLED AS PER UPS EO B747-5310-23715 APP D AND C.