As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C M/D LEFT BS 900 TENSION TIE TO FRAME CONNECTION FOUND NR 5 AND 13 HOLE CRACK AT FWD CHANNEL. CRACK LENGTH 0.030" AND 0.040". M/D LEFT BS 900 TENSION TIE FWD CHANNEL REPAIRED AS PER SRM 53-10-11 FIG 2. REPEAT INSPECTION IS REQUIRED AS PER SRM 53-10-11 FIG 2 TABLE 4 AND UPS ASSIGNED MPI P19385.