As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C M/D LEFT BS 840 TENSION TIE TO FRAME CONNECTION FOUND NR 4 HOLE CRACK AT FWD CHANNEL RUNNING UP AND DOWN. CRACK LENGTH 0.040 INCH. M/D LEFT BS 840 TENSION TIE FWD CHANNEL REPAIRED AS PER SRM 53-10-11 FIG 2. REPEAT INSPECTION IS REQUIRED AS PER SRM 53-10-11 FIG 2 TABLE 4 AND UPS ASSIGNED MPI P19389.