As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C M/D RIGHT BS 840 TENSION TIE TO FRAME CONNECTION FOUND NR 3 HOLE CRACK AT FRAME WEB DOUBLER RUNNING UP. CRACK LENGTH 0.030 INCH. M/D RIGHT BS 840 TENSION TIE TO FRAME ATTACH DOUBLER REPLACED AND INSTALLED BETWEEN STR 9R TO STR 12R AREA AS PER SRM 51-10-01 PG 9 AND 51-30-02.