INSPECTION TYPE:C M/D BETWEEN TENSION TIE RIGHT SLOPING SHEAR WEB CRACKED AT BS 820. CRACK LENGTH 1.5 INCH. M/D BETWEEN BS 820 TO BS 840 TENSION TIE RIGHT SLOPING SHEAR WEB REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.