What was found
INSPECTION TYPE:C AFT CARGO COMPT STA 1560 FRAME FOUND CRACKED ADJACENT TO SIDE GUIDE SUPPORT BRACKET AREA AT STR 39R. CRACK LENGTH .3125 INCH. AFT CARGO COMPT BS 1560 STR 39R AREA FRAME REPAIRED AS PER SRM 51-40-03 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C AFT CARGO COMPT STA 1560 FRAME FOUND CRACKED ADJACENT TO SIDE GUIDE SUPPORT BRACKET AREA AT STR 39R. CRACK LENGTH .3125 INCH. AFT CARGO COMPT BS 1560 STR 39R AREA FRAME REPAIRED AS PER SRM 51-40-03 FIG 1.