As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C DENT IN AFT CARGO FUSELAGE FRAME STA 1320, BETWEEN S25L AND S26L. TRIMMED OUT DAMAGED AREA 1.55"W X 1.10"L IAW EA 757-5362-27-A1643 STEP 1. HFEC INSPECTED AREA PER NTM 51-00-00 PT6. NO CRACK INDICATION NOTED. TRIMMED OUT .040" AROUND CUT FINAL DIMENSION 1.6"W X 1.10"L. FABBED REPAIR ANGLE IAW MAE TRAVELER T7/674692 MAT'L 7075-0 080C BATCH 481491, HEAT TREAT TO T6 LOT 20587.