As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C DENT IN AFT CARGO FUSELAGE FRAME STA 1340, BETWEEN S25L AND S26L. TRIMMED OUT DAMAGE AREA 1.56"W X 0.96"L IAW EA 757-5362-27-A1650. PRELIMINARY 1 STEP 1. HFEC AREA PER NTM 51-00-00 PT6. NO CRACK INDICATIONS NOTED. TRIMMED OUT .040" AROUND UCT FINAL DIMENSION 1.6"W X 1.00"L. REMOVED 2EA STRINGER CLIPS, 1 EA SPLICE IAW EA 757-5362-27-A 1650. ACCOMPLISHED ON FINAL EA757-5362-27-A1650 AND UPS B757-5310-2667.