As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C NR 1 PYLON AFT BULKHEAD LOWER OUTBOARD CORNER IS CHAFED. BULKHEAD MILL WAS DONE ON TRAV T7/693383 PER PRELIMINARY 1 EA B757-5453-27-A1716. HFEC WAS DONE ON TRAVELER T7/693383 PER PRELIMINARY EA B757-5453-27-A1716. LENGTH OF BLEND 2.1X1.250WX. .080D PER PRELIMINARY 1 EA B757-5453-A1716.