As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C NR 1 PYLON AFT BULKHEAD OUTBD SIDE LOWER CORNER CHAFED. BULKHEAD MILL WAS DONE ON TRAV NR T7/696069 PER PRELIMINARY 1 EA 757- 5453-27-A1725 STEP 1. HFEC WAS DONE ON TRAV NR T7/696069 PER PRELIMINARY EA 757-5453-27-A1725 STEP 2. BLEND IS 2.1 L BY 1.25W BY .080D PER PRELIMINARY 1 EA 757-5453-27-A175 STEP 3. REMAINING THICKNESS ON FLANGE IS .120 PER PRELIMINARY 1 EA 757-5453-27-A1725 STEP 4.