What was found
INSPECTION TYPE:N/A DENT IN FUSELAGE LEFT SIDE APPROX 5 FT AFT OF CREW ENTRY DOOR. ACCOMPLISHED HFEC INSP OF AREA PER NDTM PART 6, 51-00-19, NO CRACKS WERE DETECTED PP QC 0558905. ACCOMPLISHED INTERIM ACTIONS PER PARAGRAPH 6A OF EO B757-5330-27682-A. OK FOR CONTINUED SERVICE. ACCOMPLISHED PERMANENT REPAIR WITHIN 30 DAYS.