As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:SIP LEFT PYLON AFT PITCH LOAD FITTING HAS SHORT EDGE MARGIN. FABBED RADIUS FILLER FROM 7075-T7351. LOCATED, DRILLED & REAMED TO FINAL SIZE. VERIFIED RADIUS FILLER LIES FLAT AS BACKUP FITTING. ALODINED & PRIMED RADIUS FILLER PER ER 07-2696. C/W ALL REQUIREMENTS OF ER 07-2696 CUSTOMER AUTHORIZATION EO B767-5740-27262-A.