What was found
INSPECTION TYPE:ETOP EICAS MSG MAIN BATTERY CHARGER DISPLAYED. BATTERY DISCHARGE LIGHT DID NOT ILLUMINATE. SWAPPED APU BATTERY CHARGER WITH MAIN BATTERY CHARGER IAW 24-31-02-4 & 24-31-05-4. MAIN BATTERY CHARGER OPS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:ETOP EICAS MSG MAIN BATTERY CHARGER DISPLAYED. BATTERY DISCHARGE LIGHT DID NOT ILLUMINATE. SWAPPED APU BATTERY CHARGER WITH MAIN BATTERY CHARGER IAW 24-31-02-4 & 24-31-05-4. MAIN BATTERY CHARGER OPS NORMAL.