What was found
INSPECTION TYPE:C3 - FOUND IB UPPER RIB OF OB SLOT DOOR STRUCTURE HAS 4" CRACK,CENTER LEADING EDGE LW ABOVE PNEUMATIC DUCT. REMOVED, STOP DRILLED CRACK, FABRICATED AND INSTALLED 1 INTERCOSTAL, AND 1 REPAIR ANGLE IAW SRM 51-1-20D, 57-03-01-0, 51-03-02.