As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C2 CORROSION ON FLOORBEAM LOWER T-CAP EXFOLIATED STA -80 RBL 54. REMOVED OUT OF LIMITS CORROSION AT STA -80 RBL 57 IAW SRM 51-2-1. FABRICATED AND INSTALLED REPAIR PARTS AT STA -80 RBL 57 IAW SRM 51-2-1 FIG 1, AND TR 51-130.