As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C3 CRACKED END FITTING ON FLOORBEAM AT STA 280, RBL 48 A-PIT DOORWAY UPPER FWD CORNER REMOVED FLOORBEAM END FITTING AT STA 280, RBL 48 A-PIT DOORWAY UPPER FWD CORNER IAW SRM 51-1-20D. FABRICATED AND INSTALLED FLOORBEAM END FITTING AT STA 280 RBL 48 IAW DWG 974022 AND SRM 51-3-2 AND SRM 51-1-20D.