What was found
EVIDENCE OF CORROSION BETWEEN FUSELAGE SKIN, FINGER DOUBLER AND LONGERON 31R, STARTING AT STA 70 AND EXTENDING APPROX 6 FEET REFERENCE D351779 AND FERRY PERMIT 9033. [06-29-07] REMOVED LWR FWD PANEL IN "A" PIT TO ACCESS AREA PER SRM 51-3-0 & OPENED UP EXTERNAL SKIN FROM STA 70-128.0 L29R-L33R. R/R FINGER DOUBLER PER SRM 51-1-20D & 51-1-21. REMOVED CORR. AT L31R FROM STA 70-90 PER SRM 53-2-0 FIG 1F. TREATED & PRIMED PER SRM 51-1-8.