What was found
INSPECTION TYPE:C3 AFT PRESS BULKHEAD RT L10R AREA 2EA CRACKS AT STA 1766. CUT OUT DAMAGED AREA AT STA 1766 L10R IAW SRM 53-2-5 FIG 14A. FABRICATED AND INSTALLED REPAIR DOUBLER, FINGER DOUBLER, AND FILLER AT STA 1766 L10R IAW SRM 53-2-5 FIG 14A, AND SRM TR 53-194. THIS REPAIR REQUIRES A DAMAGE TOLERANCE INSP INITIAL AT 16,000 LANDINGS AND REPETIVE INSP AT 4,000 THERE AFTER IAW TR 53-194.