As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C3 DOUBLE DRILLED HOLES IN WEB AT LWR AFT CORNER OF L2 DOOR JAMB STA 1667. TRIMMED OUT DAMAGED AREA OF WEB AND FRAME SEGMENT OF L2 DOOR LWR AFT CORNER DOOR JAMB IAW DWG DC8-53A-011. FABRICATED AND INSTALLED "J" ANGLE DOUBLER AT L2 DOOR LWR AFT DOOR JAMB CORNER IAW SRM 53-02- 00 FIG 23 AND DWG DC8-53A-011.