What was found
INSPECTION TYPE:C2 A-PIT STA 120 LBL 26 FLOORBEAM GOUGED AND FASTENER SHEARED. CUT OUT DAMAGED AREA ON FLOORBEAM AT STA 120 LBL 26 IAW SRM 51-02-00, FABRICATED AND INSTALLED REPAIR ANGLES AT STA 120 LBL 26 IAW SRM 51-02-00 FIG 1, AND SRM 53-02-00 FIG 1F.