INSPECTION TYPE:C2 OVERSIZED HOLE, 2 SHEARED RIVETS IN CHAFE STRIP AND ATTACH FLANGE ON I/B END OF LEFT HORIZONTAL STAB L/E. REMOVED OUTER RUB STRIP DOUBLERS ON I/B END OF LEFT HORIZONTAL STAB L/E IAW SRM 51-1-21. FABRICATED AND INSTALLED REPAIR DOUBLERS AND FILLER AT LEFT HORIZONTAL STAB L/E IAW SRM 51-1-21, AND DWG 5644330.