What was found
INSPECTION TYPE:C LT WING, I/B FLAP O/B HINGE (FLAP SIDE) O/B LUG O/B FLANGE CORRODED. LHW IB FLAP OB HINGE AFT SIDE OB STRAP OB SURF LOCAL BLEND CORROSION REMAINING THK 0.205" AND CORROSION STILL EXIST MIN ALLOW THK 0.205" CMM57-52-03. ST ARP REMOVED SRM 51-33-01 VIIR38. FAB ARC2518-501 STRAP IAW ARC2518. FPI C/O NDTMSPMR12PT08 NO CRACK. PROTECT/PAINT SRM 51-21-01 VIIR38. HOLES PICKUP SRM 51-31-01V11 IAW ARC2512. INSTL SRM 51-33-01 VII AND DWG ARC2512.