What was found
INSPECTION TYPE:C CTR CARGO, UPPER DOOR JAMB AREA, STA 1601 FOUND WITH CORROSION UPON OPENING OF TOP BOX. CTR CARGO, UPPER DOOR JAMB AREA STA 1601 CORROSION REMOVED PER SRM 51-31-01 VOL II REV 38. MATERIAL ORIGINAL THK 0.085" STA 1601, REMOVED 0.039" REMAIN 0.046" FOUND EXCEED LIMIT PER SRM 53-00-01 FIG 1A VOL II REV 38. REPAIR SHIM AND DOUBLER FABRICATED AS PER EN1398-06 SHT 10. INSTALLED REPAIR PARTS PER EN1398-06 SHT 10.