What was found
INSPECTION TYPE:C NR 1 ENG RIGHT CORE COWL AFT LWR EDGE FOUND WITH CHAFE MARK AS MARKED. DAMAGED LONGERON AT NR 1 ENG RIGHT CORE COWL AFT LWR EDGE AREA REMOVED PER SRM 51-31-01 V-II R38. NEW LONGERON FAB PER EN 1093-07. HOLES ON FAB LONGERON PICKED UP AS PER SRM 51-31-01 V-II R38. PAINT TOUCHED UP ON REWORK AREA PER SRM 51-21-01 V-II R38. NEW LONGERON AT NR 1 ENG RIGHT CORE COWL AFT LWR EDGE AREA INSTALLED PER SRM 51-21-01 V-II R38.