What was found
INSPECTION TYPE:C RIGHT WING O/B FLAP, I/B AFT HINGE FOUND PIVOT POINT BUSHINGS 2EA CORRODED. RIGHT AFT O/B FLAP I/B HINGE PIVOT POINT BUSHINGS REMOVED PER BSOPM 20-20 -7 R56. RIGHT AFT O/B FLAP I/B HINGE PIVOT BORE & SPOTFACE CORROSION REMOVED & FOUND EXCEED LIMIT PER CMM57-52-04 PG 621-622. FPI CUTOUT IAW DAC NDT SPM R12 PT 8 ON REWORKED AREA & FOUND NO CRACK & NO CORROSION EVIDENT. BUSHINGS FAB & INSTALLED PER EN 1082-07.