What was found
INSPECTION TYPE:C CTR CARGO COMPT: ALONG BS 1781, ALONG RBL 45.75 (X=-45.75) FLOORBEAM WEB UPPER TEE FOUND CORRODED; AFTER ROLLER TRAY REMOVAL. ATTACH CORROSION AREA & INNER PARTS REMOVED FOR ACCESS PER SRM 51-31-01 V2 R38. T-CHORD UPPER CORROSION MAT REMOVED PER SRM 51-21-01 V1 R38. REPAIR TEE SUPPORT & ANGLE FAB PER EN1135-07, FPI CUTOUT ON FAB TEE & ANGLE FOUND CRACK EVIDENT. OK TO INSTALL. REPAIR TEE & ANGLE, RE-INSTALLED PER EN1135-07 & SRM 51-31-01 V2 R38, FOUND SATISFACTORY.